NFPA 701 Method 2 Drapery Flammability Tester
NFPA 701 Method 2 Drapery Flammability Tester with stainless steel open-box cabinet and Bunsen burner assembly

NFPA 701 is the Standard Methods of Fire Tests for Flame Propagation of Textiles and Films. The standard is divided into Method 1 and Method 2 according to fabric weight. This Flame Propagation Tester is manufactured in accordance with NFPA 701 Method 2 and is suitable for testing single or multi-layer fabric panels heavier than 700 g/m² (21 oz/yd²), as well as polyethylene-coated fabrics and similar materials.

Applicable Standard
  • NFPA 701: 2004 and 2010 Editions, Test Method 2
Key Features of the Flame Propagation Tester
  • Stainless steel cabinet structure with an open-box design for safe, unobstructed observation.
  • Calcium silicate board cabinet interior with stainless steel exterior packaging.
  • Imported Bunsen burner conforming to ASTM D 5025, with a fixed flame angle of 25°.
  • Automatic ignition and extinguishing mode for repeatable, operator-independent testing.
  • Needle valve flame height control for precise adjustment.
  • Automatic gas release and burning time set to 20 seconds.
  • Stainless steel wire and standard sample clip supplied with the tester.
  • Merkel burner delivering 10,500 Btu/hour of heat output.
Technical Specifications
Dimensions (L × W × H) 500 × 500 × 2420 mm
Burner Size Diameter 9.5 mm (+1.5, −0 mm), length 100 ± 10 mm
Weight 110 kg
Flow Meter Range 0 ~ 66 cc/min
Timer Range 0–99 s ± 0.1 s
Burner Operating Pressure 17.5 kPa ± 2.0 kPa
Operating Gas Flow Rate 113 L/hr ± 3 L/hr
Flame Height 280 ± 12 mm
Burner Heat Output 10,500 Btu/hour (Merkel burner)
Gas Release & Burning Time Automatically set to 20 seconds
Power Supply 220 V, 50 Hz, 110 W
Test Method 1 vs. Test Method 2: What Is the Difference?
Test Method 1

Applies to materials with a density less than or equal to 700 g/m². Typical items include draperies, curtains, and other fabrics used as window treatments, usually as single-layer fabrics. The exception is when more than one layer is fastened together by sewing or other mechanical means.

Test Method 2

Applies to plastic films, vinyl-coated fabrics such as blackout linings, and lined curtains with a vinyl coating. Decorative materials other than fabrics fall within this category. Fabrics with or without reinforcement or a backing used as interior building decoration must also pass Test 2, including permanent enclosures for buildings under construction. Awnings, plastic tarps, tents, banners, and membrane structures must meet Test 2 requirements as well. These items cannot be tested to Test 1 — only Test 2.

If you are unsure which method applies to your material, please contact the NFPA or visit their website for the complete and detailed certification requirements.