Place of Origin: | CHINA |
Brand Name: | SKYLINE |
Certification: | CE , Calibration Certificate |
Model Number: | SL-OA65 |
Minimum Order Quantity: | 1 Unit |
---|---|
Price: | negotiated |
Packaging Details: | plywood case |
Payment Terms: | L/C, D/P, T/T, Western Union, MoneyGram |
Supply Ability: | 10 unit / month |
Bias Voltage Range: | 0 ~ 500mv | Measuring Range: | 0.1~10000 Ng/μl |
---|---|---|---|
Temperature Control Range: | Room Temperature ~ 1000 ℃ | Temperature Control Accuracy: | ±1°C |
Measurement Accuracy: | Sample Concentration (ng/μl) 0.2 RSD(%)35 Sample Concentration (ng/μl) 1.0 RSD (%)10 Sample Concentration (ng/μl) 100 RSD(%)5 Sample Concentration (ng/μl)1000 RSD(%)2 | Gas Source Requirements: | General Nitrogen And General Oxygen |
Power Supply Voltage: | AC 220V±10% 50Hz±10% 3.5KW | Dimensions: | Host :410×350×75(mm) Temperature Control: 530×420×360(mm) Stirrer:290×270×360(mm) Injector:350×130×140(mm) |
Highlight: | Easy To Operate Chloride Analyzer,Microcoulomb Sulfur Chloride Analyzer |
The Microcoulomb Sulfur Chloride Analyzer is designed and manufactured according to SH/T 0253. It applies microcoulomb analysis technology, uses oxidation method to oxidize the sample into titratable ions through the cracking furnace, and titrates in the titration cell. According to Faraday's law, calculate the sulfur content in the sample, which is suitable for light petroleum products with a boiling point of 40-310°C. Samples with a sulfur content ranging from 0.5 to 1000ppm, and samples with a sulfur content greater than 1000ppm should be measured after dilution. This instrument can also measure the content of chlorine.
Man-machine direct dialogue, easy to operate
The computer controls the whole process of analysis and data processing, displays the working status of the whole process, and saves or prints the parameters and results as required.
International popular circuits and imported components are used to reduce the noise of the instrument and improve the detection sensitivity.
It has the characteristics of stable and reliable performance, easy operation, high analysis precision and good repeatability.
Bias voltage range | 0 ~ 500mv |
Measuring range | 0.1~10000 ng/μl |
Temperature control range | room temperature ~ 1000 ℃ |
Temperature control accuracy | ±1°C |
measurement accuracy |
Sample concentration (ng/μl) 0.2 RSD(%)35 Sample concentration (ng/μl) 1.0 RSD (%)10 Sample concentration (ng/μl) 100 RSD(%)5 Sample concentration (ng/μl)1000 RSD(%)2 |
Gas source requirements | general nitrogen and general oxygen |
Power supply voltage | AC 220V±10% 50Hz±10% |
Power | 3.5KW |
Dimensions |
Host :410×350×75(mm) Temperature control: 530×420×360(mm) Stirrer:290×270×360(mm) Injector:350×130×140(mm) |
Contact Person: Charlie
Tel: 13310806019
Fax: 86-769-38818154
ISO 5660 AC220V Cone Calorimeter For Building Materials Testing
Fire Testing Equipment Steiner Tunnel Test Apparatus
BIFMA 5.1 Furniture Testing Equipment Chair Seat Impact Testing Machine
SL-TL01 Luggage Walking Bump Test Machine/ Running Machine / Castor Test Machine
IS5967 Strength Testing Equipment , Stability Testing Equipment For Tables And Trolleys