Place of Origin: | CHINA |
Brand Name: | BMC |
Certification: | CE |
Model Number: | Y-30T |
Minimum Order Quantity: | 1 unit |
---|---|
Price: | negotiated |
Packaging Details: | CARTON BOX |
Delivery Time: | 10 working days |
Payment Terms: | T/T |
Supply Ability: | 3000 unit/ month |
Pressure Range: | 4-30cm H2O(±0.5cm H2O) | Ventilator: | For ICU In Breathing Machines |
---|---|---|---|
Brand: | BMC | Ventilation Mode: | CPAP,S,S/T,T |
After-sale Service: | Online Technical Support | Type: | Electronic Control |
Highlight: | BiPAP Non Invasive Respiratory Machine,CPAP Non Invasive Respiratory Machine,ICU Portable Medical Ventilator |
CPAP BiPAP S/T Non invasive respiratory machine portable medical ventilator
Y series BPAP Systems are Bi-level PAP (Bi-level Positive Airway Pressure) devices intended to
provide non-invasive ventilation for patients with Obstructive Sleep Apnea (OSA) and Respiratory
Insufficiency. They are intended for adult patients by prescription in the home or hospital/institutional
environment. With its Target Tidal Volume function and other excellent comfort features and effective
performance, it offers each patient personalized ventilation support.
Model Comparison
Y-30T | IPAP: 4 -30 hPa EPAP: 4 -25 hPa C PAP m ode: 4 -20 hPa |
3.5-inch | CPAP, S, T, S/T |
Specification
Name | Y-30T non invasive ventilators |
Pressure range | 4-30cm H2O(±0.5cm H2O) |
Pressure accuracy | ±0.5cm H2O |
Delayed boost | 0-60min, set the division interval 5min |
Initial pressure | 4cm H2O treatment pressure / respiratory pressure setting |
Therapeutic pressure | 4-20cm H2O (in CPAP mode) |
Target tidal volume | 150ml - 1500ml, on / off |
Maximum suction pressure | 4-30cm H2O, (can be set when the target tidal volume funct |
Minimum suction pressure | 4-30cm H2O (not higher than suction pressure)can be set |
Inspiratory phase pressure | 4-30cm H2O |
Expiratory pressure | 4-30cm H2O |
Inspiratory time | 0.3-3.0s |
backup rate | On / off, default 10 |
Ramp
The ramp time ranges from 0 to 60 minutes
Humidifier
Humidifier Settings: off, 1 to 5 (95°F to 167°F
/ 35°C to 75°C)
Humidifier Output: No less than 10 mg H2O/L
SpO 2
Range: 0 to 100%
Pulse Rate
Range: 40 to 240 BPM
Sound Pressure Level
< 30 dB, when the device is working at the pressure of 10 hPa
Storage
SD card can record patient data and fault information
AC Power Consumption
100 - 240 V AC, 50/60 Hz, Max 2 A
Key Parameters
Target Vt: On/ Off
150~1500 mL
Reslex: Patient, Off, 1~3
I Sens.: 1~8
E Sens.: 1~8
Res Rate: 3~40 BPM
Ti: 0.3-3.0s
Rise Time: 1~4
Contact Person: Charlie
Tel: 13310806019
Fax: 86-769-38818154
ISO 5660 AC220V Cone Calorimeter For Building Materials Testing
Fire Testing Equipment Steiner Tunnel Test Apparatus
BIFMA 5.1 Furniture Testing Equipment Chair Seat Impact Testing Machine
SL-TL01 Luggage Walking Bump Test Machine/ Running Machine / Castor Test Machine
IS5967 Strength Testing Equipment , Stability Testing Equipment For Tables And Trolleys