Place of Origin: | CHINA |
Brand Name: | BMC |
Certification: | CE |
Model Number: | Y-30T |
Minimum Order Quantity: | 1 unit |
---|---|
Price: | negotiated |
Packaging Details: | CARTON BOX |
Delivery Time: | 10 working days |
Payment Terms: | T/T |
Supply Ability: | 3000 unit/ month |
Pressure Range: | 4-30cm H2O(±0.5cm H2O) | Ventilator: | For ICU In Breathing Machines |
---|---|---|---|
Brand: | BMC | Ventilation Mode: | CPAP,S,S/T,T |
After-sale Service: | Online Technical Support | Type: | Electronic Control |
High Light: | BiPAP Non Invasive Respiratory Machine,CPAP Non Invasive Respiratory Machine,ICU Portable Medical Ventilator |
CPAP BiPAP S/T Non invasive respiratory machine portable medical ventilator
Y series BPAP Systems are Bi-level PAP (Bi-level Positive Airway Pressure) devices intended to
provide non-invasive ventilation for patients with Obstructive Sleep Apnea (OSA) and Respiratory
Insufficiency. They are intended for adult patients by prescription in the home or hospital/institutional
environment. With its Target Tidal Volume function and other excellent comfort features and effective
performance, it offers each patient personalized ventilation support.
Model Comparison
Y-30T | IPAP: 4 -30 hPa EPAP: 4 -25 hPa C PAP m ode: 4 -20 hPa |
3.5-inch | CPAP, S, T, S/T |
Specification
Name | Y-30T non invasive ventilators |
Pressure range | 4-30cm H2O(±0.5cm H2O) |
Pressure accuracy | ±0.5cm H2O |
Delayed boost | 0-60min, set the division interval 5min |
Initial pressure | 4cm H2O treatment pressure / respiratory pressure setting |
Therapeutic pressure | 4-20cm H2O (in CPAP mode) |
Target tidal volume | 150ml - 1500ml, on / off |
Maximum suction pressure | 4-30cm H2O, (can be set when the target tidal volume funct |
Minimum suction pressure | 4-30cm H2O (not higher than suction pressure)can be set |
Inspiratory phase pressure | 4-30cm H2O |
Expiratory pressure | 4-30cm H2O |
Inspiratory time | 0.3-3.0s |
backup rate | On / off, default 10 |
Ramp
The ramp time ranges from 0 to 60 minutes
Humidifier
Humidifier Settings: off, 1 to 5 (95°F to 167°F
/ 35°C to 75°C)
Humidifier Output: No less than 10 mg H2O/L
SpO 2
Range: 0 to 100%
Pulse Rate
Range: 40 to 240 BPM
Sound Pressure Level
< 30 dB, when the device is working at the pressure of 10 hPa
Storage
SD card can record patient data and fault information
AC Power Consumption
100 - 240 V AC, 50/60 Hz, Max 2 A
Key Parameters
Target Vt: On/ Off
150~1500 mL
Reslex: Patient, Off, 1~3
I Sens.: 1~8
E Sens.: 1~8
Res Rate: 3~40 BPM
Ti: 0.3-3.0s
Rise Time: 1~4
Contact Person: Kate Guo
Tel: 13310805373
Building Materials Flammability Tester NF P92-505 Melt Dripping Test Apparatus
ASTM E162 900 Celsius Building Materials Flammability Tester For Radiant Panel
Building Materials Flammability Flame Spread Tester
ASTM E1354 HEAT RELEASE CONE CALORIMETER WITH OXYGEN ANALYZER
Fire Testing Equipment Heat Transfer Index Test Apparatus
Wire And Cable Heat Release Test Device
UL Cable Vertical Tray Fire Testing Equipment
NFPA 1971-2007 Fire Helmet Fire Resistance Combustion Test Device
Automatic Ignitability Building Materials Flammability Tester For Building Materials
Foam Plastics Horizontal and Vertical Flammability Tester with MCU Control
Lab Building Materials Flammability Tester , UL1685 Vertical Tray Test Chamber for Cables