logo
Products
Home / Products / Building Materials Flammability Tester /

SBI Building Products Single Burning Item Building Materials Flammability Tester / Device EN13823

SBI Building Products Single Burning Item Building Materials Flammability Tester / Device EN13823

Brand Name: SKYLINE
Model Number: SL-FL080
MOQ: 1 unit
Price: negotiated
Payment Terms: T/T, L/C, Western Union
Supply Ability: 1 unit/ month
Detail Information
Place of Origin:
China
Certification:
CE
SKYLINE:
Single Burning Item Flammability Testing Device / SBI
Standards:
EN13823
Testing Room Dimension:
L(3.0±0.2)m× W(3.0±0.2)m× H(2.4±0.1)m
Exhause Speed:
0.50 M3 /S~0.65 M 3/ S
Temperature:
0-400℃; Accuracy ±0.5
CO2 Test Range:
0-10%
O2 Test Range:
0-25%
Relative Humidity:
<90%
Packaging Details:
plywood case
Supply Ability:
1 unit/ month
Highlight:

horizontal flammability tester

,

vertical flammability chamber

Product Description

SBI Building Products Single Burning Item Flammability Testing Equipment / Device EN13823
 

Features

1.The core part of the machine are imported components: such as carbon dioxide, oxygen analysis equipment.

2.Operating interface style and performance equivalent to the United Kingdom FTT, some performance is better.

3.Easy maintenance, fast, late parts replacement than FTT minimum less than 50% to 70%, there will be no maintenance problems.

4.With imported integrated control cabinet.

 

Technical parameters

1.Composition: this test equipment includes combustion laboratory, control room, 2 small carts, exhaust pipe, fixed frame, flue gas collection system, integrated measurement system device, data collection and analysis device, gas supply control device.

2.Combustion chamber: long (3.0 ± 0.2) m × width (3.0 ± 0.2) m × high (2.4 ± 0.1) m.

3.With stainless steel plate and calcium silicate board A1 plate composed of standard combustion chamber, test furnace should be installed at local;

4.At the top of the room there is a collecting hood and a smoke pipe connecting the sampling piping. The combustion heat release and combustion products of the sample are discharged from the exhaust pipe during the test.

5.Combustion chamber on a wall set up an opening, easy to enter the small cart, under the trolley air naturally out of space; vertical test plate on both sides of the front surface of the two sides were opened on the observation window.

6.Ignition source, placed in the trolley on the vertical corner of the 31KW propane right angle sandbox burner (side length 250MM high 80MM).

7.The position of the cart is to place the opening of the cart on the back of the cart just to close the openings in the combustion chamber wall. To distribute the airflow evenly along the combustion chamber floor, a perforated plate (perforated) is arranged at the air inlet at the bottom of the trolley Diameter 8mm, open area accounted for 60% of the total area).

8.With adjustable governance fixture, loading and unloading samples is very convenient.

9.Sandbox burner: one on the floor of the trolley (main burner), the other fixed on the frame column, propane gas through the sandbox burner and produce 30.7 ± 2.0kW heat output.

 

Oxygen measurement

 Measuring range  0-25%
 Signal output  4-20mA
 Response time T90  ≤2S;
 Ambient temperature  0-45 ℃;
 Relative humidity  <90% (non-condensing)
 Linearity  <± 0.1% O2
 Zero drift  0.05% O2 per week
 Repeatability  <± 0.02% O2
 Carbon dioxide(CO2) measurement  
 Measuring range  0-10%
 Repeatability  <± 1% internal structure of the control cabinet;
 Zero drift  ≤2% / week
 Span drift  ≤2% / week
 Linearity deviation  <± 1%
 Response time  T90≤2 seconds

 

Record data acquisition system can collect oxygen concentration, carbon monoxide concentration, temperature, smoke density, heat release rate, mass loss rate, etc., can be stored.

SBI.pdf

Test principle
A sample consisting of two vertically angled vertical wings is exposed to the flame produced by the main burner at the bottom of the right angle, the flame is produced by the combustion of propane gas, the propane gas passes through the sandbox burner and produces (30.7 ± 2.0) kW of heat output.


The combustion performance of the sample was evaluated by the entire test procedure of 20 min. Performance parameters include: heat release, smoke production, flame propagation and burning dripping and particulate matter.


Prior to igniting the main burner, the heat output and smoke generation of the burner itself should be measured for a short time using the auxiliary burner remote from the sample.


Some parameters can be measured automatically, while others can be obtained by visual inspection. The smoke pipe is equipped with a sensor for measuring the temperature, light attenuation, the mole fractions of O2 and CO2, and the airflow in the pipeline. These values are automatically recorded and used to calculate the volumetric flow rate, heat release rate (HRR) and smoke rate (SPR).


The transverse propagation and burning of the flame and the particulate matter can be measured using a visual method.

 

 

Applications

 

- Fire performance classification testing for building materials and products

- CE-mark fire testing for construction products

- Reaction-to-fire assessment during new product development

- Quality control and outgoing inspection on production lines

- R&D of decorative materials and thermal insulation products

- Third-party laboratory and institutional research applications

 

Frequently Asked Questions

 

Q1: What standards does the SL-FL13 comply with?

A1: It complies with EN 13823 and GB/T 20284-2006. Test results support EN 13501-1 classifications from A2 through D.

 

Q2: What materials can be tested?

A2: Building materials, decorative products, thermal insulation systems, and construction products excluding floorings—any material requiring reaction-to-fire classification.

 

Q3: What key parameters does it measure?

A3: HRR, THR, FIGRA, SPR, TSP, SMOGRA, LFS, and burning droplets—all parameters required for EN 13501-1 or GB 8624 classification.

 

Q4: How accurate and stable is the system?

A4: Very. Fully automated heating, ignition, and data acquisition minimise variability. The gas analyser responds in under 3 seconds, and step calibration verification ensures Q_gas/HRR ratio remains within (100 ± 5)%.

 

Q5: Is the equipment easy to operate?

A5: Yes. The intuitive software interface handles automatic ignition, gas control, and data logging. On-site training is included with every installation.

 

Q6: What after-sales support do you provide?

A6: One-year warranty plus lifetime technical support. We cover installation, calibration, test method development, and CMA/CNAS accreditation consulting.

 

Single Burning Item Flammability Testing Equipment...

 

SBI Building Products Single Burning Item Building Materials Flammability Tester / Device EN13823  SBI Building Products Single Burning Item Building Materials Flammability Tester / Device EN13823