Xenon lamp aging test chamber before operation inspection and operation methods, precautions

China SKYLINE INSTRUMENTS CO.,LTD certification
China SKYLINE INSTRUMENTS CO.,LTD certification
Thank you for a very very fast quote. I'm really impressed.

—— Abdul Malek (Malaysia)

Dealing with the Seller was no problem at all. We are in Chicago IL and the order arrived in less days than I thought and everything was good. Thanks

—— Roger( America)

Very Good to deal with! Great Communication through Email. I got it in no time.....less than 5 days.....

—— Raymond(America)

We have recieved the equipment and done the first tests with it. It works without any problem and we are happy with the product quality. Many Thanks

—— Ercan Arslan (Turkey)

Thanks for your prompt reply and excellent customer service.

—— Lisa (America)

Confirming I have received the items and very happy with the quality. Thanks again and we will keep you in mind for future equipment!

—— David Kraus(America)

Always great to work with Skyline!

—— Tharrett Dallas

I'm Online Chat Now
Company News
Xenon lamp aging test chamber before operation inspection and operation methods, precautions
Latest company news about Xenon lamp aging test chamber before operation inspection and operation methods, precautions

The equipment needs to do the following checks before use in order to be used safely.

1. check whether the power supply voltage and power meet the requirements of the equipment.

2. check whether the power cord is properly connected in accordance with the specifications, and indeed reliably grounded.

3. check whether the water inlet of the equipment has been connected to the water source.

4. check whether the equipment drainage pipeline is connected.

5. check whether the equipment circuit is faulty.

 

Operation method of Xenon lamp aging test chamber

1、Put the sample into the box to fix and close the door.

2、Connect the power cord, turn on the main power switch, the power indicator light is on

3, press the "run switch", the instrument has a display.

 

In the process of using the equipment, the following matters should be paid special attention to avoid danger.

 

1, in the operation, unless necessary, please do not open the box door, otherwise it may lead to adverse consequences.

l high and low temperature steam rushed out of the box ............ Very dangerous

l the inside of the door still remains high temperature ........ cause burns

l strong ultraviolet radiation .................. Causes burns to the skin

2、Please note that the machine must be safely grounded to avoid electrostatic induction.

3、It is absolutely prohibited to test explosive, combustible and highly corrosive substances.

4、Check whether the working environment of the equipment is up to standard. If you have any questions, please

Pub Time : 2022-11-09 17:44:21 >> News list