Send Message
SKYLINE INSTRUMENTS CO.,LTD

        Skyline Instruments Co.,LTD

 

                   We only manufacture Lab Testing Equipment

Home
Products
VR Show
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home News

Function introduction of acid-base potentiometric titrator

China SKYLINE INSTRUMENTS CO.,LTD certification
China SKYLINE INSTRUMENTS CO.,LTD certification
Thank you for a very very fast quote. I'm really impressed.

—— Abdul Malek (Malaysia)

Dealing with the Seller was no problem at all. We are in Chicago IL and the order arrived in less days than I thought and everything was good. Thanks

—— Roger( America)

Very Good to deal with! Great Communication through Email. I got it in no time.....less than 5 days.....

—— Raymond(America)

We have recieved the equipment and done the first tests with it. It works without any problem and we are happy with the product quality. Many Thanks

—— Ercan Arslan (Turkey)

Thanks for your prompt reply and excellent customer service.

—— Lisa (America)

Confirming I have received the items and very happy with the quality. Thanks again and we will keep you in mind for future equipment!

—— David Kraus(America)

Always great to work with Skyline!

—— Tharrett Dallas

I'm Online Chat Now
Company News
Function introduction of acid-base potentiometric titrator
Latest company news about Function introduction of acid-base potentiometric titrator

Automatic Oil PH Tester Oil Analysis Testing Equipment

 

 

Introduction Of Automatic Oil PH Tester

 

Multi-functional potentiometric titrator for measuring mercaptan sulfur, basic nitrogen, acid value, base value, etc.is designed in strict accordance with relevant national standards. The instrument consists of three parts: hardware circuit, titration device and PC. With the support of application software, the determination of substance content by method determination. The instrument has simple structure, beautiful appearance, high degree of automation and accurate analysis results. It is an ideal intelligent instrument for petrochemical laboratories, analysis rooms and scientific research departments.

 

 

Precautions for Automatic Oil PH Tester


1. The input end (electrode socket) of the instrument must be kept dry and clean. When the instrument is not in use, insert the Q9 short-circuit plug into the socket to prevent the intrusion of dust and water vapor.
2. During measurement, the lead wire of the electrode should be kept still, otherwise the measurement will be unstable.
3. When calibrating the instrument with a buffer solution, the reliability of the buffer solution should be ensured, and the buffer solution should not be mismatched, otherwise the measurement will be inaccurate.
4. After removing the electrode cover, the sensitive glass bulb of the electrode should be avoided from contact with hard objects, because any damage or rubbing will make the electrode invalid.
5. The external reference (or calomel electrode) of the composite electrode should always pay attention to the presence of saturated solution, and the supplementary solution can be added from the small hole at the upper end of the electrode.
6. The electrode should avoid long-term immersion in distilled water, protein solution and acidic fluoride solution.

Pub Time : 2022-09-21 18:02:57 >> News list