Place of Origin: | CHINA |
Brand Name: | SKYLINE |
Certification: | CE , Calibration Certificate |
Model Number: | SL-OA52 |
Minimum Order Quantity: | 1 Unit |
---|---|
Price: | negotiated |
Packaging Details: | plywood case |
Payment Terms: | L/C, D/P, T/T, Western Union, MoneyGram |
Supply Ability: | 10 unit / month |
Hydrogen Flame Ionization Detector (FID: | Cylindrical Collector Structure Design, Metal Nozzle | Detection limit: | ≤2×10-12g/s (n-hexadecane/isooctane) |
---|---|---|---|
Baseline noise: | ≤10μV | Baseline drift: | ≤100μV/30min |
Linearity: | ≧105 | Adjustable fully automatic ignition, stabilization time: | 30 Minutes |
Thermal Conductivity Detector (TCD): | Semi-diffused Structure, Constant Current Control Mode For Power Supply | Sensitivity: | ≥5000mV·ml/mg |
Temperature range: | 5°C~420°C Above Room Temperature Accuracy ±0.1°C | Power supply: | 220V±22V, 50Hz |
Power: | ≥2kW | Weight: | 55KG |
Dimensions: | 60cm×50cm×50cm | ||
High Light: | Semi Diffused Structure Gas Chromatograph,Insulating Oil Gas Chromatograph |
It is designed and manufactured according to the methods stipulated in GB/T 17623 and DL/T 703 standards, and is suitable for analyzing oil-filled electrical equipment (including transformers, reactors, current transformers, voltage transformers, charging bushings, etc.) Analysis of hydrogen, carbon monoxide, methane, carbon dioxide, ethylene, ethane, acetylene and other gas content in oil.
Realize computer real-time control and data processing:
High-precision, stable and reliable temperature control system:
The heater will stop heating and report the fault location on the display;
Simple and clear man-machine dialogue interface, easy to operate, easy to learn and use
Double stable high-precision air path control system.
The column chamber adopts the method of tracking temperature rise.
The instrument detects low-level hydrocarbons and high-level CO and CO2, which can be detected separately to avoid mutual interference.
Hydrogen Flame Ionization Detector (FID) | Cylindrical collector structure design, metal nozzle |
Detection limit | ≤2×10-12g/s (n-hexadecane/isooctane) |
Baseline noise | ≤2×10-13A |
Baseline drift | ≤2×10-12A/30min |
Linearity | ≥106 |
Adjustable fully automatic ignition, stabilization time | 30 minutes |
Thermal Conductivity Detector (TCD) | Semi-diffused structure, constant current control mode for power supply |
Sensitivity | ≥5000mV·ml/mg |
Baseline noise | ≤10μV |
Baseline drift | ≤100μV/30min |
Linearity | ≧105 |
Temperature range | 5°C~420°C above room temperature Accuracy ±0.1°C |
Power Supply | 220V±22V, 50Hz |
Power | ≥2kW |
Weight | 55KG |
Dimensions | 60cm×50cm×50cm |
Contact Person: Charlie
Tel: 13310806019
Fax: 86-769-38818154
ISO 5660 AC220V Cone Calorimeter For Building Materials Testing
Fire Testing Equipment Steiner Tunnel Test Apparatus
BIFMA 5.1 Furniture Testing Equipment Chair Seat Impact Testing Machine
SL-TL01 Luggage Walking Bump Test Machine/ Running Machine / Castor Test Machine
IS5967 Strength Testing Equipment , Stability Testing Equipment For Tables And Trolleys