SKYLINE INSTRUMENTS CO.,LTD

        Skyline Instruments Co.,LTD

 

                   We only manufacture Lab Testing Equipment

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsFlammability Testing Equipment

Digital Oxygen Index Tester Box Material Divided Steel Plate Electrostatic Spraying

Digital Oxygen Index Tester Box Material Divided Steel Plate Electrostatic Spraying

    • Digital Oxygen Index Tester Box Material Divided Steel Plate Electrostatic Spraying
  • Digital Oxygen Index Tester Box Material Divided Steel Plate Electrostatic Spraying

    Product Details:

    Place of Origin: China
    Brand Name: SKYLINE
    Certification: CE
    Model Number: SL-FL100

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 unit
    Price: negotiated
    Packaging Details: plywood case
    Delivery Time: 10 work days
    Payment Terms: T/T, L/C, Western Union, MoneyGram
    Supply Ability: 1 unit/ month
    Contact Now
    Detailed Product Description
    Building Material: Flammability Testing Equipment Ignitability Tester Standards: GB / T 2406.2-2009
    Digital Resolution: ± 0.1% Box Size: 835 X Depth 400 X High 815mm
    Materail: 1.5mm Stainless Steel Touch Panel: 7 Inch Effective Display, Size 15.5cm Wide 8.6cm
    Flow Adjustment Range: 0-10L / Min (60-600L / H) Resolution: 800*480: 800*480

    Digital Oxygen Index Tester Box Material Divided Steel Plate Electrostatic Spraying
     

    Technical parameters 

    1. Use imported oxygen sensor, digital display without concentration of oxygen, higher accuracy and accuracy, the range of 0- 100%
    2. Digital resolution: ± 0.1%
    3. Machine measurement accuracy: 0.4 level
    4. Flow adjustment range: 0-10L / min (60-600L / h)
    5. Response time: <5S
    6. Quartz glass tube: diameter ≥ 75 mm high 300mm
    7. Gas flow rate in the combustion cylinder: 40mm ± 2mm / s The total height of the combustion tube 450mm
    8. Gauge accuracy of 2.5, resolution: 0.01Mpa Gauge accuracy 2.5, resolution: 0.01MPa
    9. Flowmeter: 1-15L / min (60-900L / H) adjustable, accuracy of 2.5
    10. Test environment: Ambient temperature: room temperature ~ 40 ℃, relative humidity: ≤ 70%;
    11. Input pressure: 0.2-0.3MPa
    12. Working Pressure: Nitrogen 0.05-0.15Mpa Oxygen 0.05-0.15Mpa Oxygen / Nitrogen Mixing Gas Inlet: Includes Regulator, Flow Regulator, Gas Filter and Mixing Chamber.
    13. Sample holder can be used for soft and hard plastics, textiles, fire doors and so on
    14. Propane (butane) ignition system, flame length 5mm-60mm can be adjusted freely
    15. Gas: industrial nitrogen, oxygen, purity> 99%; (user-owned).
    16. Power Requirements: AC220 (+ 10%) V, 50HZ
    17. The maximum use of power: 50W
    18. Ignition: a metal tube made of, the end of the inner diameter of Φ2 ± 1mm nozzle, can be inserted into the combustion tube lit sample, flame length: 16 ± 4mm, adjustable size
    19. Spontaneous material sample holder: can be fixed in the combustion tube axial position, and can vertically clamp the sample
    20. Non-self-supporting material sample holder: the sample can be fixed at the same time the two vertical sides of the frame

     
    Standards
    GB / T 2406.2-2009
     
    Chassis and part of the structure

    1. Control box: The use of CNC machining molding machine, steel spraying spray electrostatic box, the control part of the experimental part of the separate control.

    2. Burning tube: high-temperature high-quality quartz glass tube (diameter ¢ 75mm, length 300mm) outlet diameter: φ40mm

    4.Mixer: Glass beads filled form, mixing oxygen and nitrogen evenly. (Bead φ4.5mm fill height 95mm, a bag)

    5. Sample Fixture: Self-supporting clamp, and can vertically clamp the sample; (optional non-self-supporting type sample rack), two sets of sample clip to meet different test requirements; Clip more simple

    7. quipped with a standard glass tube to prevent accidental damage to meet the needs of uninterrupted testing; pole rod end tube diameter ¢ 2 ± 1mm, igniter flame length (5-50) mm can be adjusted.

     

    Packing List

    1. Host one set
    2. burning tube one set
    3. Igniter one
    4. Power cord one
    5. spare glass tube one
    6. Glass beads one bag (into the combustion column)
    7. Nylon tube Ф4 1.2 meters (connecting the combustion column with the host)
    8. Seal Some
    9. pointed sample holder one set
    10. Metal mesh one (into the combustion column)
    11. Stainless steel outlet plate one
    12. Rubber tube two roots
    13. M10 × 1 inner connector screw one (connected to the combustion column)
    14. M10 × 1 joint nut one (host)
    15. Instructions one
    16. Non-self-supporting sample holder one set (to be optional)

    Tips: oxygen index tester test required not less than 98% of the industrial-grade oxygen / nitrogen bottle as a gas source, as the above gases for high-risk transport products, can not be used as oxygen index analyzer accessories, only the user local Gas station to buy. (In order to ensure the purity of gas, please purchase at the local regular gas station)
     

    Contact Details
    SKYLINE INSTRUMENTS CO.,LTD

    Contact Person: Kasey Xie

    Tel: 18370826024

    Send your inquiry directly to us (0 / 3000)

    Other Products